yy-9-core-0-75mm-unshielded-copper-control-cable-sensor-wiring-300/500v-vde-0250-ce-rohs, yy-9-core-0-75mm-unshielded-copper-control-cable-sensor-wiring-300/500v-vde-0250-ce-rohs, /control-cable
EN
YY 9 Core 0.75mm unshielded copper control cable is rated 300/500V for sensor wiring. It adopts IEC60228 Class5 fine-stranded bare copper conductor with outstanding bending resistance, operating between -20℃ and +70℃. This VDE 0250, CE and RoHS compliant cable is designed for industrial automation wiring, supplied with various core marking and full OEM custom options.
YY Flexible PVC Unshielded Control Cable for CNC Machines is intended for low-voltage control, monitoring, measurement, and data-related connections inside industrial equipment. It provides a multi-core wiring option for machine builders who need to connect controllers, sensors, actuators, and auxiliary devices in an orderly way.
The supplied construction information describes flexible IEC 60228 Class 5 bare-copper conductors with PVC insulation and a PVC outer sheath. This combination supports routing through panels, enclosures, and machine assemblies where a flexible control-circuit cable is appropriate.
Cable selection should begin with the circuit and the route. Confirm required conductors, cross-section, protective-conductor arrangement, terminals, pathway, and environmental exposure before assigning a final part configuration.
The documented rated voltage is 300/500V and the stated test voltage is 2000V. The stated working-temperature range is -20°C to +70°C. VDE 0250 is named as a reference standard, and flame-retardant performance is stated to IEC 60332-1-2.
These values are product information, rather than a substitute for a complete machine review. The responsible designer should compare the selected cable, protective devices, terminals, installation method, and any required local rules with the actual application.
The outer layer and insulation are PVC. PVC construction can be a sensible choice for the documented control application, but it does not by itself establish suitability for every chemical, temperature, sunlight, or motion condition.
For fixed routing, the listed minimum bend radius is five times the cable outside diameter. For mobile installation, the listed value is ten times the outside diameter. Actual bend space therefore depends on the chosen core count and conductor size.
Available core conventions include JZ and JB versions with a green-yellow protective conductor, and OZ and OB versions without one. Numbered black cores or colour-coded cores can be selected to support the wiring schedule and reduce ambiguity during installation.
Tight cabinet exits, conduit changes, and frame pass-throughs deserve particular attention. A route that appears adequate on a layout can become restrictive once glands, sleeves, terminals, and the actual outside diameter are included.
YY Flexible PVC Unshielded Control Cable for CNC Machines has an unshielded construction. It can be considered where the circuit and equipment environment do not call for electromagnetic screening. It should not be specified on the assumption that it will control EMI simply because it is used in automation equipment.
If the route passes near drives, switching devices, high-noise conductors, or sensitive signal circuits, assess the system rather than treating the cable as an isolated choice. Separation, grounding arrangements, connector compatibility, and a shielded cable design may all require consideration.
For CNC cabinets and machine tools, the intended use can include organized connections among control components. For production machinery, it can group multi-core wiring where the stated electrical and environmental limits fit the project.
The listed construction range starts with 2 × 0.5 mm² and 2 × 0.75 mm² options and extends to multi-core versions such as 18 × 0.5 mm² and 18 × 0.75 mm². Reported outside diameter and weight change with the construction.
For reference, the supplied information lists 2 × 0.5 mm² at 5.0 mm outside diameter and 35 kg/km. The 2 × 0.75 mm² example is listed at 5.6 mm and 46 kg/km. Confirm the precise selected variant before calculating conduit fill, gland sizing, reel handling, or terminal space.
Before routing, first verify circuit needs; then verify the bend path and protection method; finally verify core marking, termination, and environment. This sequence is more reliable than selecting only by a nominal voltage label.
The product material describes limited oil resistance in accordance with DIN EN 50290-2-22 and chemical resistance at room temperature. If the installation faces continuous coolant, oil, unusual chemicals, strong UV, or severe flexing, validate the actual exposure before approval.
YY Flexible PVC Unshielded Control Cable for CNC Machines is not described as a direct-burial product. For an outdoor route, protective conduit or trunking should be considered unless a UV-resistant sheath has been explicitly agreed. For a moving application, do not assume that general flexibility equals suitability for drag-chain service.
Protecting the sheath from sharp edges, excessive bending, and poor support is a practical part of installation planning. It can also make later inspection and maintenance less difficult.
The documented customization scope covers core count, conductor cross-section, core identification, sheath colour, print marking, cable length, and packing. Providing those details with the wiring schedule supports an engineering review before a purchase decision.
The stated minimum order quantity is 100 meters. Standard packing is listed as 100 m or 305 m (1000 ft) per spool or coil, carton packed. The supplied commercial information states 7-15 days after order confirmation and a supply ability of 300,000 meters per month; verify final pricing, configuration, and lead time for the actual order.
The value of YY Flexible PVC Unshielded Control Cable for CNC Machines is a documented flexible PVC option for a defined control circuit. It is most useful when its configuration, route, environment, and unshielded limitation are reviewed together with the complete machine design.
For a machine project, review the cable schedule alongside the electrical drawing before release. Identify every controlled device, the terminal assignment, the planned route, and the expected service condition. This makes it easier to distinguish a fixed internal connection from a route that has repeated movement, exposure, or noise-control requirements.
Record the selected core count and cross-section, then compare the selected outside diameter with cabinet entry points, conduit space, bend allowance, and support locations. Check whether a protective conductor is required and whether the chosen JZ, JB, OZ, or OB designation matches the drawing. Those checks are simple, but they prevent late changes after cable preparation has started.
Also review the surrounding equipment. Where control and power conductors share a cabinet, route planning and separation can affect the result as much as the cable selection itself. If the project introduces unusual fluids, high temperatures, sunlight, vibration, or continuous movement, treat those as validation questions rather than assumptions. The supplied product information should be compared with the conditions that will actually occur in service.
YY 9 Core 0.75mm unshielded copper control cable is rated 300/500V for sensor wiring. It adopts IEC60228 Class5 fine-stranded bare copper conductor with outstanding bending resistance, operating between -20℃ and +70℃. This VDE 0250, CE and RoHS compliant cable is designed for industrial automation wiring, supplied with various core marking and full OEM custom options.