liyy-300v-flexible-pvc-data-transmission-cable, liyy-300v-flexible-pvc-data-transmission-cable, /data-transmission-cable
EN
LiYY flexible multicore PVC data cable adopts Class5 fine‑stranded copper conductors for high flexibility. Featuring compact lightweight PVC/PVC structure, 300V rated, it fits indoor signal‑control wiring, offers multiple core‑size selections and supports practical OEM custom options.
LiYY 300V Flexible PVC Data Transmission Cable is a multicore option for indoor low-voltage data, signal, and control wiring. It uses Class 5 fine-stranded copper conductors, PVC core insulation, and a PVC outer sheath. This construction can bring several circuits into one compact route inside control cabinets, equipment enclosures, monitoring devices, switchboards, and general automation equipment. It is intended for fixed installation or occasional movement when the chosen configuration and routing conditions match the stated limits.
The purpose of this cable is organized multicore routing, not an unlimited flexibility claim. Fine-stranded conductors can simplify handling in a cabinet or a restricted enclosure, but a flexible cable is not automatically suitable for continuous high-frequency flexing, torsional movement, or drag-chain travel. Selection should begin with the circuit count, conductor section, route, bend allowance, temperature range, and expected movement. That sequence helps align the construction with the application instead of relying on the product name alone.
| Model | LiYY |
|---|---|
| Rated voltage | 300V |
| Conductor | Class 5 fine-stranded copper, IEC 60228 |
| Insulation / sheath | PVC / PVC |
| Core identification | Colour-coded according to DIN 47100 |
| Operating temperature | -20°C to +70°C |
| Minimum bending radius | Fixed: 4 x OD; occasional movement: 10 x OD |
| Flame performance | IEC 60332-1-2 |
| Sheath colour | Black, grey, or customised |
Multiple core-count and conductor-section options are available. Nominal outer diameter and weight vary with the selected construction, so final values should be confirmed before production, conduit planning, or installation. The supplied material gives examples from 2 x 0.25 mm² upward, but the correct version depends on the number of circuits, conductor section, and physical route required by the equipment.
Class 5 conductors provide practical routing flexibility through equipment housings, cable trays, and control cabinets. First check the route and working clearance, then select the core count and section, and finally confirm the installation method. This approach keeps the handling benefit connected to the real assembly requirement.
A bundled construction can reduce the complexity of separate low-voltage control or signal runs in panel wiring and modular equipment. It can support orderly installation where conduit or cable-management space is limited. The exact outside diameter is configuration-specific, so cable entries, clips, fill ratio, and clearance need review against the final version.
Colour-coded cores according to DIN 47100 support circuit recognition during assembly, documentation, maintenance, and troubleshooting. For installations containing several signal or control circuits, this may make a consolidated route easier to identify, provided the required core arrangement is confirmed in advance.
The supplied specification states 300V service and an operating temperature range of -20°C to +70°C. The insulation and outer covering are described for practical indoor installation. Where routing passes near motors, relays, contactors, variable-frequency drives, or other noise sources, use suitable separation, routing, and grounding practice. The available material does not establish a shielded construction; do not represent this product as a shielded solution where verified EMC protection is required.
LiYY 300V Flexible PVC Data Transmission Cable can be considered for electronic control equipment, measuring instruments, sensors, computer and monitoring systems, low-voltage switchgear, machine-tool control circuits, office equipment, and general automation equipment. In a control panel, it can consolidate colour-identified circuits. In an equipment enclosure, it can provide a manageable multicore route where space is restricted.
For stationary wiring, apply the stated minimum bending radius of four times the cable outer diameter. For occasional movement, use ten times the outer diameter as the stated guidance. A catalogue radius is a minimum reference rather than an invitation to force a turn at a terminal, clip, or enclosure corner. Allow practical installation room and avoid crushing, sharp forced turns, or a route that converts occasional movement into repetitive travel.
Flexibility can be useful during installation, but it is not the same as verified continuous dynamic duty. If an application includes repeated travel, high bend frequency, torsion, or a demanding electrical-noise environment, state those conditions during technical review. A construction specifically verified for that duty may be more appropriate. Clear requirements prevent a general request for flexible routing from being interpreted as a request for drag-chain performance.
LiYY 300V Flexible PVC Data Transmission Cable supports discussion of core count, conductor cross-section, sheath colour, print marking, packing length, and cut length. OEM/ODM support is stated for custom requirements, subject to confirmation against the intended application and final production specification. Listed packing is 100 m, 200 m, or 300 m per coil or reel, with carton or wooden-reel packing. The listed minimum order quantity is 100 meters; stated delivery is 7-15 days after order confirmation, and stated supply ability is 300,000 meters per month.
For a useful inquiry, provide the required cores and section, nominal voltage, route, fixed or occasional movement condition, ambient temperature, requested marking or sheath colour, packing preference, and any electrical-noise concern. This allows the selected construction to be reviewed against the actual project before order confirmation.
This multicore cable combines fine-stranded copper, colour-identified cores, and a compact construction for indoor signal and control wiring. Its appropriate role is a project that needs organized routing within the stated electrical, temperature, and movement boundaries. A review of the route and final configuration remains the sensible last step before production.
LiYY flexible multicore PVC data cable adopts Class5 fine‑stranded copper conductors for high flexibility. Featuring compact lightweight PVC/PVC structure, 300V rated, it fits indoor signal‑control wiring, offers multiple core‑size selections and supports practical OEM custom options.