CY Single Core 50mm Shielded Copper Control Cable Earth Feeder 300/500V PVC VDE 0250 CE

CY Single Core 50mm shielded copper control cable serves as an earth feeder, rated 300/500V. It uses IEC60228 Class5 fine-stranded bare copper conductor with ≥80% tinned copper braid for excellent EMI shielding. Constructed with flexible PVC, it has a wide working temperature range. This VDE 0250 and CE approved cable fits industrial automation and CNC wiring, with multiple core marking and OEM custom options available.

Request a Quote
  • Overview

Overview

CY Flexible PVC Tinned Copper Shielded Control Cable for CNC

The CY Flexible PVC Tinned Copper Shielded Control Cable for CNC is a flexible multi-core cable for control, measurement, monitoring, and signal-transmission work in industrial equipment. It is intended for applications where equipment builders need orderly routing together with a shielded construction. The product uses fine-stranded bare copper conductors stated as IEC 60228 Class 5, PVC core insulation, a PVC outer sheath, and a tinned copper wire braid with stated coverage of at least 80%. This combination supports flexible installation while helping address electromagnetic interference around motors, switching devices, and other electrically noisy equipment.

For a CNC machine, a control cabinet, or a production-line assembly, cable selection should begin with the circuit function and the installation route. The CY Flexible PVC Tinned Copper Shielded Control Cable for CNC is a control cable rather than a substitute for every power, data, or motion-rated cable. Its shield is designed to improve interference protection, but shielding performance also depends on correct termination and continuity throughout the installation. In other words, a braided shield is useful only when the complete system design and grounding approach are reviewed.

Verified Construction and Ratings

Item Stated specification
Model CY
Conductor Fine-stranded bare copper, IEC 60228 Class 5
Insulation / sheath PVC / PVC
Shielding Tinned copper wire braid, at least 80% coverage
Rated voltage 300/500V
Test voltage 2000V
Operating temperature -20°C to +70°C
Flame retardancy IEC 60332-1-2

The stated minimum bending radius is five times the cable outer diameter for fixed installation and ten times the cable outer diameter for mobile installation. This distinction matters in equipment design: a cable can be flexible for routing, yet a moving path still needs adequate bend space and strain management. Where a project requires continuous flexing, torsion, drag-chain duty, oil exposure beyond the stated limited resistance, or a special environmental rating, confirm suitability against the actual application before specifying the cable.

Functional Features

  • Flexible conductor construction: IEC 60228 Class 5 fine-stranded copper supports routing through compact equipment and control panels.
  • Braided EMI shield: the stated tinned copper braid helps improve electromagnetic compatibility in locations near drives and switching equipment.
  • PVC insulation and sheath: the product description identifies a flexible PVC construction with good mechanical performance and limited oil resistance under normal industrial conditions.
  • Core identification options: JZ and JB versions include a green-yellow protective conductor, while OZ and OB versions are supplied without one.
  • Project adaptability: core count, conductor cross-section, sheath colour, printing, cable length, and packing may be customised.

A 2.5 flex cable requirement, for example, should be confirmed by the requested core arrangement and conductor cross-section rather than by a search phrase alone. The available dimensional information includes multiple core counts and sections, from 2 x 0.5 mm² through listed larger combinations. Outer diameter and weight vary with the exact construction, so procurement teams should request the required configuration when comparing quotations or planning routing space.

Applications for CNC and Automation

The CY Flexible PVC Tinned Copper Shielded Control Cable for CNC is described for industrial automation, machine tools, production lines, control cabinets, electromechanical assemblies, and machinery requiring stable control and signal performance. In a CNC environment, it can be considered for suitable control circuits where flexible routing and a braided shield are relevant. In a control cabinet, it can support organised interconnection between components when the voltage rating, installation method, and circuit requirements match the stated product data.

It is also relevant to measurement, monitoring, instrumentation, and control circuits. These applications often share a practical concern: interference is not solved by a cable claim alone. First, identify the noise sources and signal sensitivity; then verify routing separation, shielding continuity, termination, and grounding practice. This approach helps the engineering team match a shielded control cable to the system rather than relying on a single parameter.

For machinery builders, the declared black sheath is the standard option, while other colours can be supplied for equipment identification or project requirements. Marking, length, and packing can likewise be tailored for a defined build. The stated commercial terms list a 100-metre minimum order quantity and 100 m / 305 m spool or coil packaging, with carton packing. Delivery and pricing should be confirmed for the selected construction and order requirements.

Selection Notes

When selecting this cable, begin with the required number of cores, conductor size, voltage, environment, and route geometry. Then confirm whether a protective conductor is required and choose the appropriate JZ, JB, OZ, or OB identification option. Finally, check the fixed or mobile bending radius against the available installation space. A tighter physical route than the stated radius can create avoidable installation stress, even where the cable is otherwise suitable.

The CY Flexible PVC Tinned Copper Shielded Control Cable for CNC is differentiated by its stated Class 5 copper conductor, PVC construction, and tinned copper braided shield, alongside configurable core identification and project options. It is best evaluated as one part of an automation system. For a precise quotation or technical review, provide the required core count, cross-section, shielding expectation, colour, length, packing, and intended installation conditions. This allows the selected cable construction to be checked against the actual CNC or industrial-control application.

Installation Planning

Before release to production, document the route, required core count, conductor cross-section, shielding termination method, and installation motion. Check the selected cable outer diameter against gland, conduit, tray, and bend-space constraints. Keep control wiring separated from higher-noise circuits where the equipment design requires it. For fixed installation, use the stated five-times-outer-diameter minimum bending radius; for mobile installation, use the stated ten-times-outer-diameter requirement. Avoid sharp edges and provide appropriate mechanical protection at entry points. If the installation includes coolant, oil, heat, or continuous movement outside the described normal industrial conditions, obtain application confirmation. These steps do not change the cable rating; they help ensure that the chosen configuration, termination practice, and mechanical route are reviewed together before installation.

CY Single Core 50mm Shielded Copper Control Cable Earth Feeder 300/500V PVC VDE 0250 CE

CY Single Core 50mm shielded copper control cable serves as an earth feeder, rated 300/500V. It uses IEC60228 Class5 fine-stranded bare copper conductor with ≥80% tinned copper braid for excellent EMI shielding. Constructed with flexible PVC, it has a wide working temperature range. This VDE 0250 and CE approved cable fits industrial automation and CNC wiring, with multiple core marking and OEM custom options available.

Request a Quote

Featured Products

500v pvc vde 0250 ce-1

Get a Free Quote

Our representative will contact you soon.
Email
Mobile Or WhatsApp
Name
Company Name
Message
0/1000